A resistor element is used to define a thermal resistance between two nodes in the model. In the
element generation, two nodes in the model are referenced. The order with which the nodes are
selected is not important. A fixed value for the value of the resistor can be entered or the element
can reference the property table. The value of the resistor can be made a function of the
distance between the referenced nodes by entering a zero for resistance in the property table and
a value for Kx. The resistor can be time or temperature dependent by having the property table
entry reference the array data.
Select Add>Resistor.
STEP 1 - Define the value of the resistor by either entering its value in the Resistance value edit
box or by referencing a property. A resistor element need not reference a property. There are
several reasons why a property should be referenced.
1) If the resistance varies with time or temperature, then a property must be referenced. The
appropriate property entry can then reference array data which defines the dependency.
2) If it is expected that the resistance is going to change on subsequent runs of the model, the
value of the resistor can be easily changed by referencing a property.
3) Referencing a property can define the resistance to be a function of the distance between the
two referenced nodes or one which is based on convective heat transfer. These are explained
below.
Select Add Property to add a property or select an existing property from the drop down list.
The Value edit box will now be titled Factor. Enter a value in the Factor edit box. For details on
the actual resistance used in the solution, see below. Select Information>Property to change
the property value later.
STEP 2 - Check the Select First Node checkbox then select the first node. Next either enter a
node number in the First Node edit box or pick the node from the screen.
STEP 3 - Using the mouse, select the second node from the screen.
The resistor elements will be drawn to the screen. Resistor elements are represented by lines
drawn from the First Node to the Second Node. The color of the lines will either be the color
defined in the Render dialog for Resistors or the color of the referenced property. More resistor
elements can be generated or the OK button can be selected to end the operation.
Values used during model solution
If the Resistor element references a property:
1) Resistance value is entered in the property:
The resistance value used during the model solution is the product of the value entered in the Value/Factor edit box and the value in the referenced property. This type of resistor adds no
capacitance to a transient model.
2) Value for Kx (zero for resistance) entered in the property:
The resistance value used during the model solution is defined by the following equation.
where the delta term is the distance between the nodes defining the resistor,
A is in the referenced property for Area,
k is in the referenced property for Kx, and
f is the Factor defined in the dialog when the element was created.
For a transient analysis, the capacitance of the nodes at the end of the resistor will be calculated
as follows;
Capacitance=Area*density*Specific heat*distance/2
Where density and specific heat are found in the material referenced by the property. Area is
defined in the referenced property. Distance is the distance between the two referenced nodes.
3) Value for H.T. Coeff (zero for resistance and Kx) entered in property table:
The resistance used during the model solution is defined by the following equation.
where h is the heat transfer coefficient defined in the referenced property,
A is the Area defined in the referenced property and
f is the Factor defined in the dialog when the element was created.
This type of resistor adds no capacitance to a transient model.
Time or temperature dependencies
The resistance can be time or temperature dependentby having the value in the property or
material reference array data.
Resistance value entered in the referenced property:
The resistance value used during the model solution is the product of the value entered in the
Value/Factor edit box, the value in the referenced property and the interpolated value from the
array data referenced in the property.
Value for Kx (zero for resistance) entered in the property table:
The resistance value used during the model solution is the value calculated above times the
interpolated value from the array data referenced in the material referenced by the property for
Kx.
Value for H.T. Coeff (zero for resistance and Kx) entered in property table:
The resistance value used during the model solution is the value calculated above times the
interpolated value from the array data referenced in the property for H. T. Coeff.