To have Solaria perform a check on the model select Solve>Check Model or the graphic toolbar. When the Check Model button is hit in the Check Model dialog, the model will be checked for things like missing properties, array data or invalid elements.  When an error is found a message identifying the element and problem will be written in the scrollable text area on the dialog box.  If the Transient checkbox is checked, a check will be made to ensure that density and specific heat is defined for all geometric elements. The data is saved in the Undo/Redo buffer.

The following summarizes what is checked.

Geometric elements on top of each other, share all the same corner nodes. 

For this check to work, the model must be equivalenced other wise the corner nodes may be at the same location, but they will not share node numbers.

If two or more of the same element type is found sharing the same nodes, the following dialog will come up.

graphic

Skip

            If Skip is hit then nothing is done.

Skip All

If this option is selected then nothing is done for all elements found.

Delete duplicates

            If this option is selected, for this element all duplicates are deleted leaving one element at
            that location.  When another duplicate is found, the dialog will come up again.

Delete all duplicates

            If this option is selected then for all elements that are found with duplicates, the
            duplicates are deleted leaving one element at that location.  This dialog will not come
            up again.

Geometric elements

            Property not referenced
            Property doesn't reference a material
            Material thermal conductivity is zero
            If transient, specific heat or density is zero
            For 2D Plates, if thickness is zero
If the geometry of the element is not defined correctly, the following dialog will come up.

graphic

Skip

            If Skip is hit then nothing is done.

Skip All

If this option is selected then nothing is done for all elements found.

Delete element

            If this option is selected the element will be deleted.  When another is found,
the dialog will come up again.

Delete all bad elements

            If this option is selected then for all bad elements will be deleted 
This dialog will not come up again.



Convection

            The HTC/factor defined in the dialog is zero
            If a property is referenced and the HTC is zero
            If a proper ambient node is not defined

Node to Node Radiation

The value/factor defined in the dialog is zero
If a property is referenced, a material is not referenced
Area or View factor in the property table or emissivity in the material is zero

Node to Surface Radiation

The value/factor defined in the dialog is zero
If a property is referenced, a material is not referenced
View factor in the property table or emissivity in the material is zero
If a proper ambient node is not defined

Resistor

The value/factor defined in the dialog is zero
If a property is referenced, the property data is not defined properly

Interface

A property is not referenced
If the type is radiation, a material is not referenced
if the type is radiation and a material is referenced, emissivity is zero

Flow

The value/factor defined in the dialog is zero
If a property is referenced, MdotCp is zero

Nodal Heat

The value/factor defined in the dialog is zero
If a property is referenced, Nodal Heat is zero

Surface Heat

The value/factor defined in the dialog is zero
If a property is referenced, Surface Heat is zero

Volume Heat

The value/factor defined in the dialog is zero
If a property is referenced, Volume Heat is zero