If a model has a periodic or cyclic heat load which continues for an indefinite period of time, the
temperatures from pulse to pulse will increase until a quasi steady state condition is achieved.
The temperatures of consecutive pulses will be the same. To reach this condition can take many
pulses. To achieve this same condition quicker, determine the long-term average power
dissipation and apply it to the model. Run the model to determine steady state temperatures.
Next apply the transient time dependent heat load to the model. With the steady state
temperatures as initial conditions, run the model for three or four pulses or until temperatures in
consecutive pulses are the same. If the temperatures after the transient run are not the same,
load temperatures from the transient run at the end of the run and use these as the initial
temperature to run a couple more pulses. This method is much quicker than running the model
until this state is achieved.

Temperatures for the first three pulses with isothermal (all the same) temperatures as the initial
conditions.
Temperatures for the first four pulses with the average temperatures as the initial conditions. As
seen the temperatures during the third and forth pulses are very close to the same.