Heat loads can be added directly to nodes. Before adding heat loads to nodes of the model it is a
good idea to select Solve>Compact Nodes first. This will remove all nodes which are not
attached to elements of the model. If this is not done it is possible to add heat to nodes which are
not attached to elements of the model and therefore will not be part of the solution.
Select Add>Heat Load>Nodal
Enter the value of the heat load in the Heat Load/Factor edit box. This value of heat will be
added to each node selected. A heat load need not reference the property table. There are
several reasons why the property table should be referenced.
1) If the heat load varies with time or temperature, then the property table must be referenced.
The appropriate property entry can then reference array data which defines the dependency.
2) If it is expected that the heat load is going to change on subsequent runs of the model, the
value of the heat load can be easily changed by using the property table.
3) Within the property table a variable can be referenced. This way many values can be changed
by simply changing a single value.
Select Add Property to add a property to the property table or select an existing property from the
drop down list. The value used is explained below. Select Modify>Property to change the
property later.
To select a node, first hit the Select button.
More heat loads can be generated or the OK button can be selected to end the operation.
Values used during model solution
· Heat loads references the property table:
The heat load used during the model solution is the product of the value entered in the Heat
Load/Factor edit box and the value in the referenced property table.
· Property table references array data:
The heat load used during the model solution is the product of the value entered in the Heat
Load/Factor edit box, the value in the referenced property table and the interpolated value from
the array data referenced in the property table. If any of the three values is zero, then no heat
load is added.
· The property table references a Variable:
The heat load used during the model solution is the product of the value entered in the Heat
Load/Factor edit box, the value of the referenced Variable and the interpolated value from the
array data referenced in the property table. If any of the three values is zero, then no heat load is
added.