Calculating Brick Resistances
Valid geometry
Solaria can accurately represent any shaped brick element. This should not be confused with
model accuracy though. If there results a significant temperature gradient within a single brick
element then the element mesh should be finer if the temperatures at these nodes are of interest.
Conversion to resistors
Prior to solving the model all brick elements are converted into resistances. The value of the
resistances is a function of the geometry of the element (the location of the nodes defining the
brick) and the thermal conductivity as defined in the referenced property table. For brick
elements whose internal angles are all 90 degrees and whose thermal conductivity is isotropic
(the same in all directions), twelve resistors are calculated based on the following formula:
where D is the distance between the nodes and K is the thermal conductivity of the element. The
area, A, is the cross sectional area for that portion of the element. This is calculated as the
product of half the width of the element normal to the heat flow in both directions for that resistor.
This is shown as the shaded area in the figure below for the resistor going from Node 1 to Node
2.
If the internal angles of a brick element are not all 90 degrees or the thermal conductivity is
anisotropic then the brick element is represented by 28 resistors. The actual conversion to
resistors uses a finite element solution. The resistors generates are shown below. A resistor
connects every node to every other node.
A similar method is used for wedge shaped elements. Fifteen resistances represent this shaped
brick element.