Prior to solving a Solaria model, the entire model is converted into a resistor network. For
transient solutions, capacitances are calculated at all node locations. The following lists the
quantity of resistors generated by element type.
Resistor 1
Plate 4
or 6
Triangular Plate 3
Brick 28
Wedge shaped Brick 15
Tetrahedron 4
Convection 3 or 4
Node to Node radiation 1
Node to Surface radiation 3 to 5
Surface to Surface radiation 3 to 5
Fluid flow 1
per segment
Combining Parallel Resistances
For heat to be transferred between elements of the model, they must share nodes. Because of
this, in the process of calculating resistances, many resistors are generated between the same
nodes. The model could be solved at this point but the solution would be inefficient. To speed
the solution, resistors in the model which go between the same nodes are combined prior to the
solution. If the resistances are fixed (not time or temperature dependent) or are time or
temperature dependent and reference the same set of array data, they are combined into a single
resistor using the following equation:
This process takes only a few seconds on a very large model but can reduce the size of the
model by 2 to 4 times. The number of resistors in the final solution is given in the run status
dialog box.