Solaria contains a finite difference solver. This technique performs a heat balance at each node
in the model. This entails calculating the node temperature based on the resistance and the
temperatures of all nodes attached to the node in question.
For resistors, capacitance’s, radiation, heat loads and boundary nodes whose values are
temperature dependent, for a steady state solution, their value is updated per the number of
iterations defined in the Solve>Steady State dialog box. In a transient solution their values are
updated every iteration.
Steady state solution
All resistor data is streamlined to result in a fast running solution. The following finite difference
solution routine is used for steady state solutions.
where;
Ti is the new calculated temperature of the node for which the heat balance is being performed
Told is the temperature of the node for which the heat balance is being performed for the
previous iteration
T(i+1) is the temperature of the node connected to the node Ti by the resistor R(i+1)
Qi is the total heat load on the node for which the heat balance is being performed. This may be
a fixed value and/or a temperature dependent value
The summations are for all resistors attached to the node for which the heat balance is being
performed. The variable damp is a damping coefficient. The initial value is specified in the
Solve>Steady State dialog. The default value is one, no damping. If the solution routine senses
that the routine is diverging rather than converging then this coefficient is reduced by 0.05. This
continues each iteration until the solution begins to converge. From then on, that damping
coefficient is used. If severe diverging is sensed then this coefficient is immediately given a value
of 0.25. Damping is only needed in some nonlinear solutions, ones with radiation, variable
material properties. This equation is performed on all nodes in the model.
Transient solution
All resistor data is streamlined to result in a fast running solution. The following finite difference
solution routine is used for transient solutions.
For arithmetic nodes:
where;
Ti is the new calculated temperature of the node
Told is the temperature of the node for the previous iteration
T(i+1) is the temperature of the node connected to the node Ti by the resistor R(i+1)
Qi is the total heat load on the node for which the heat balance is being performed.
is the capacitance of the node. The summations are for all resistors attached to the
node.